GUDEADS-ENC2191-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32 FROM SNMPv2-SMI OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF; gudeads MODULE-IDENTITY LAST-UPDATED "200703051356Z" -- Mar 5, 2007 1:56:00 PM ORGANIZATION "Gude Analog- und Digitalsysteme GmbH" CONTACT-INFO "http://www.gudeads.com/" DESCRIPTION "" REVISION "200703051356Z" -- Mar 5, 2007 1:56:00 PM DESCRIPTION "$Id:$" -- 1.3.6.1.4.1.28507 ::= { enterprises 28507 } enc2191POE OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "0 = no POE, 1 = POE available" MAX-ACCESS read-only STATUS current DESCRIPTION "signals POE availability" -- 1.3.6.1.4.1.28507.61.1.5.10 ::= { enc2191IntSensors 10 } gadsENC2191 OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61 ::= { gudeads 61 } -- Notification Types -- events OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.3 ::= { gadsENC2191 3 } -- Scalars and Tables -- enc2191Objects OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.1 ::= { gadsENC2191 1 } enc2191CommonConfig OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.1.1 ::= { enc2191Objects 1 } enc2191SNMPaccess OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.1.1.1 ::= { enc2191CommonConfig 1 } enc2191TrapCtrl OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3" -- 1.3.6.1.4.1.28507.61.1.1.1.1 ::= { enc2191SNMPaccess 1 } enc2191TrapIPTable OBJECT-TYPE SYNTAX SEQUENCE OF Enc2191TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list of all Trap receiver" -- 1.3.6.1.4.1.28507.61.1.1.1.2 ::= { enc2191SNMPaccess 2 } enc2191TrapIPEntry OBJECT-TYPE SYNTAX Enc2191TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "an entry containing management informations regarding the list of trap receivers" INDEX { enc2191TrapIPIndex } -- 1.3.6.1.4.1.28507.61.1.1.1.2.1 ::= { enc2191TrapIPTable 1 } Enc2191TrapIPEntry ::= SEQUENCE { enc2191TrapIPIndex Integer32, enc2191TrapAddr OCTET STRING } enc2191TrapIPIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each receiver slot." -- 1.3.6.1.4.1.28507.61.1.1.1.2.1.1 ::= { enc2191TrapIPEntry 1 } enc2191TrapAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..99)) MAX-ACCESS read-write STATUS current DESCRIPTION "DNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot." -- 1.3.6.1.4.1.28507.61.1.1.1.2.1.2 ::= { enc2191TrapIPEntry 2 } enc2191DeviceConfig OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.1.2 ::= { enc2191Objects 2 } enc2191IntActors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.1.3 ::= { enc2191Objects 3 } enc2191relayports OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.1.3.1 ::= { enc2191IntActors 1 } enc2191portNumber OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Relay Ports" -- 1.3.6.1.4.1.28507.61.1.3.1.1 ::= { enc2191relayports 1 } -- the Interfaces table -- The Interfaces table contains information on the entity's -- interfaces. Each sub-layer below the internetwork-layer -- of a network interface is considered to be an interface. enc2191portTable OBJECT-TYPE SYNTAX SEQUENCE OF Enc2191portEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list of all EPC Relay Ports" -- 1.3.6.1.4.1.28507.61.1.3.1.2 ::= { enc2191relayports 2 } enc2191portEntry OBJECT-TYPE SYNTAX Enc2191portEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular relay port." INDEX { enc2191PortIndex } -- 1.3.6.1.4.1.28507.61.1.3.1.2.1 ::= { enc2191portTable 1 } Enc2191portEntry ::= SEQUENCE { enc2191PortIndex Integer32, enc2191PortName OCTET STRING, enc2191PortState INTEGER, enc2191PortSwitchCount Integer32, enc2191PortStartupMode INTEGER, enc2191PortStartupDelay Integer32, enc2191PortRepowerTime Integer32 } enc2191PortIndex OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each Relay Port." -- 1.3.6.1.4.1.28507.61.1.3.1.2.1.1 ::= { enc2191portEntry 1 } enc2191PortName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-write STATUS current DESCRIPTION "A textual string containing name of a Relay Port." -- 1.3.6.1.4.1.28507.61.1.3.1.2.1.2 ::= { enc2191portEntry 2 } enc2191PortState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "current state of a Relay Port" -- 1.3.6.1.4.1.28507.61.1.3.1.2.1.3 ::= { enc2191portEntry 3 } enc2191PortSwitchCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of switch actions ocurred on a Relay Port. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here." -- 1.3.6.1.4.1.28507.61.1.3.1.2.1.4 ::= { enc2191portEntry 4 } enc2191PortStartupMode OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), laststate(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "set Mode of startup sequence (off, on , remember last state)" DEFVAL { off } -- 1.3.6.1.4.1.28507.61.1.3.1.2.1.5 ::= { enc2191portEntry 5 } enc2191PortStartupDelay OBJECT-TYPE SYNTAX Integer32 UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay in sec for startup action" DEFVAL { 0 } -- 1.3.6.1.4.1.28507.61.1.3.1.2.1.6 ::= { enc2191portEntry 6 } enc2191PortRepowerTime OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay in sec for repower port after switching off" DEFVAL { 0 } -- 1.3.6.1.4.1.28507.61.1.3.1.2.1.7 ::= { enc2191portEntry 7 } enc2191ExtActors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.1.4 ::= { enc2191Objects 4 } enc2191IntSensors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.1.5 ::= { enc2191Objects 5 } enc2191VoltageInfo OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.1.5.7 ::= { enc2191IntSensors 7 } enc2191ExtSensors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.1.6 ::= { enc2191Objects 6 } enc2191SensorTable OBJECT-TYPE SYNTAX SEQUENCE OF Enc2191SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.61.1.6.1 ::= { enc2191ExtSensors 1 } enc2191SensorEntry OBJECT-TYPE SYNTAX Enc2191SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { enc2191SensorIndex } -- 1.3.6.1.4.1.28507.61.1.6.1.1 ::= { enc2191SensorTable 1 } Enc2191SensorEntry ::= SEQUENCE { enc2191SensorIndex Integer32, enc2191TempSensor Integer32, enc2191HygroSensor Integer32, enc2191InputSensor INTEGER, enc2191AirPressure Integer32, enc2191DewPoint Integer32, enc2191DewPointDiff Integer32 } enc2191SensorIndex OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.61.1.6.1.1.1 ::= { enc2191SensorEntry 1 } enc2191State3V OBJECT-TYPE SYNTAX INTEGER { on(1), error(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Show state of internal 3.3V" -- 1.3.6.1.4.1.28507.61.1.5.7.2 ::= { enc2191VoltageInfo 2 } enc2191TempSensor OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "actual temperature" -- 1.3.6.1.4.1.28507.61.1.6.1.1.2 ::= { enc2191SensorEntry 2 } enc2191HygroSensor OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 percent humidity" MAX-ACCESS read-only STATUS current DESCRIPTION "actual humidity" -- 1.3.6.1.4.1.28507.61.1.6.1.1.3 ::= { enc2191SensorEntry 3 } enc2191InputSensor OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "logical state of input sensor" -- 1.3.6.1.4.1.28507.61.1.6.1.1.4 ::= { enc2191SensorEntry 4 } -- Conformance -- enc2191Conf OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.2 ::= { gadsENC2191 2 } -- Groups -- enc2191Groups OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.2.1 ::= { enc2191Conf 1 } -- Compliance -- enc2191Compls OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.2.2 ::= { enc2191Conf 2 } enc2191BasicGroup OBJECT-GROUP OBJECTS { enc2191TrapCtrl, enc2191TrapIPIndex, enc2191TrapAddr, enc2191portNumber, enc2191PortIndex, enc2191PortName, enc2191PortState, enc2191PortSwitchCount, enc2191PortStartupMode, enc2191PortStartupDelay, enc2191PortRepowerTime, enc2191ActiveInputs, enc2191InputIndex, enc2191Input, enc2191State12V, enc2191State3V, enc2191POE, enc2191SensorIndex, enc2191TempSensor, enc2191HygroSensor, enc2191InputSensor, enc2191AirPressure, enc2191DewPoint, enc2191DewPointDiff } STATUS current DESCRIPTION "Basic objects." -- 1.3.6.1.4.1.28507.61.2.1.1 ::= { enc2191Groups 1 } enc2191NotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { enc2191SwitchEvtPort, enc2191InputEvt, enc2191TempEvtSen, enc2191HygroEvtSen, enc2191InputEvtSen, enc2191AirPressureEvtSen, enc2191DewPtDiffEvtSen, enc2191POEEvt } STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.61.2.1.2 ::= { enc2191Groups 2 } enc2191Inputs OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.61.1.5.6 ::= { enc2191IntSensors 6 } enc2191InputEntry OBJECT-TYPE SYNTAX Enc2191InputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { enc2191InputIndex } -- 1.3.6.1.4.1.28507.61.1.5.6.2.1 ::= { enc2191InputTable 1 } Enc2191InputEntry ::= SEQUENCE { enc2191InputIndex Integer32, enc2191Input INTEGER } enc2191Input OBJECT-TYPE SYNTAX INTEGER { lo(0), hi(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Input state of device" -- 1.3.6.1.4.1.28507.61.1.5.6.2.1.2 ::= { enc2191InputEntry 2 } enc2191ActiveInputs OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of suppported Input Channels." -- 1.3.6.1.4.1.28507.61.1.5.6.1 ::= { enc2191Inputs 1 } enc2191InputTable OBJECT-TYPE SYNTAX SEQUENCE OF Enc2191InputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.61.1.5.6.2 ::= { enc2191Inputs 2 } enc2191InputIndex OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.61.1.5.6.2.1.1 ::= { enc2191InputEntry 1 } enc2191State12V OBJECT-TYPE SYNTAX INTEGER { off(0), low(1), high(2), error(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Show state of internal 12V" -- 1.3.6.1.4.1.28507.61.1.5.7.1 ::= { enc2191VoltageInfo 1 } enc2191AirPressure OBJECT-TYPE SYNTAX Integer32 UNITS "1 hPA (hectopascal) ~ 1 milibar" MAX-ACCESS read-only STATUS current DESCRIPTION "actual air pressure" -- 1.3.6.1.4.1.28507.61.1.6.1.1.5 ::= { enc2191SensorEntry 5 } enc2191DewPoint OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "dew point for actual temperature and humidity" -- 1.3.6.1.4.1.28507.61.1.6.1.1.6 ::= { enc2191SensorEntry 6 } enc2191DewPointDiff OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "difference between dew point and actual temperature (Temp - DewPoint)" -- 1.3.6.1.4.1.28507.61.1.6.1.1.7 ::= { enc2191SensorEntry 7 } enc2191POEEvt NOTIFICATION-TYPE OBJECTS { enc2191POE} STATUS current DESCRIPTION "Power over Ethernet changed" -- 1.3.6.1.4.1.28507.61.3.8 ::= { events 8 } enc2191InputEvt NOTIFICATION-TYPE OBJECTS { enc2191InputIndex, enc2191Input} STATUS current DESCRIPTION "Change of device input." -- 1.3.6.1.4.1.28507.61.3.2 ::= { events 2 } enc2191HygroEvtSen NOTIFICATION-TYPE OBJECTS { enc2191SensorIndex, enc2191HygroSensor} STATUS current DESCRIPTION "hygro limits exceeded" -- 1.3.6.1.4.1.28507.61.3.4 ::= { events 4 } enc2191InputEvtSen NOTIFICATION-TYPE OBJECTS { enc2191SensorIndex, enc2191InputSensor} STATUS current DESCRIPTION "change of logical input sensor state" -- 1.3.6.1.4.1.28507.61.3.5 ::= { events 5 } enc2191AirPressureEvtSen NOTIFICATION-TYPE OBJECTS { enc2191SensorIndex, enc2191AirPressure} STATUS current DESCRIPTION "Air Pressure limits exceeded " -- 1.3.6.1.4.1.28507.61.3.6 ::= { events 6 } enc2191DewPtDiffEvtSen NOTIFICATION-TYPE OBJECTS { enc2191SensorIndex, enc2191DewPointDiff} STATUS current DESCRIPTION "Dew Point Difference limits exceeded" -- 1.3.6.1.4.1.28507.61.3.7 ::= { events 7 } enc2191TempEvtSen NOTIFICATION-TYPE OBJECTS { enc2191SensorIndex, enc2191TempSensor} STATUS current DESCRIPTION "temperature limits exceeded" -- 1.3.6.1.4.1.28507.61.3.3 ::= { events 3 } enc2191SwitchEvtPort NOTIFICATION-TYPE OBJECTS { enc2191PortIndex, enc2191PortName, enc2191PortState, enc2191PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when a port is switched" -- 1.3.6.1.4.1.28507.61.3.1 ::= { events 1 } END